Aangeboden door depressie, woensdag 22 juli 2026 19:13, 36 views

Advertentiedetails


Vraagprijs € 5,-
Verzendkosten Exclusief
Staat Goede staat
Garantie Nee
Verzending ophalen, (pakket)post nationaal en (pakket)post internationaal
Betaling contant, bank vooraf, paypal vooraf en betaalverzoek

Beschrijving

Gebruikte SSHD.

Smart:
=== START OF INFORMATION SECTION ===
Model Family: Seagate Laptop SSHD
Device Model: ST500LM000-1EJ162
Serial Number: W370SM1N
LU WWN Device Id: 5 000c50 06ab65e9c
Firmware Version: DEM6
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database 7.3/6157
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Jul 22 19:08:10 2026 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 139) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 99) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x1081) SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 111 099 006 Pre-fail Always - 0/30421152
3 Spin_Up_Time 0x0003 098 098 085 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 098 098 020 Old_age Always - 2202
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 086 060 030 Pre-fail Always - 0/443519887
9 Power_On_Hours 0x0032 067 067 000 Old_age Always - 29728
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 098 098 020 Old_age Always - 2261
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 071 000 Old_age Always - 35 35 37
189 High_Fly_Writes 0x003a 001 001 000 Old_age Always - 173
190 Airflow_Temperature_Cel 0x0022 069 049 045 Old_age Always - 31 (Min/Max 27/32)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 487
193 Load_Cycle_Count 0x0032 055 055 000 Old_age Always - 91861
194 Temperature_Celsius 0x0022 031 051 000 Old_age Always - 31
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 199 000 Old_age Always - 11
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 28116 (209 159 0)
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 32224870853
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 46142175731
254 Free_Fall_Sensor 0x0032 001 001 000 Old_age Always - 136

SMART Error Log Version: 1
ATA Error Count: 2
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 2 occurred at disk power-on lifetime: 3992 hours (166 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 71 03 80 04 11 40 Device Fault; Error: ABRT

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
b0 da 00 00 4f c2 00 00 00:32:31.782 SMART RETURN STATUS
ea 00 00 00 00 00 00 00 00:32:31.615 FLUSH CACHE EXT
61 00 08 38 b1 19 48 00 00:32:31.614 WRITE FPDMA QUEUED
61 00 08 78 1f 52 42 00 00:32:31.612 WRITE FPDMA QUEUED
61 00 08 38 b1 19 48 00 00:32:28.346 WRITE FPDMA QUEUED

Error 1 occurred at disk power-on lifetime: 2798 hours (116 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 01 01 00 00 00 00 02:25:26.741 READ VERIFY SECTOR(S)
60 00 01 ff ff ff 4f 00 02:25:10.399 READ FPDMA QUEUED
b0 d8 00 00 4f c2 00 00 02:25:10.399 SMART ENABLE OPERATIONS
e5 00 00 00 00 00 00 00 02:25:10.399 CHECK POWER MODE
ec 00 00 00 00 00 00 00 02:25:10.354 IDENTIFY DEVICE

SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 29727 -
# 2 Short offline Completed without error 00% 2297 -
# 3 Short offline Completed without error 00% 2153 -
# 4 Short offline Completed without error 00% 1700 -
# 5 Short offline Completed without error 00% 3 -

SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

The above only provides legacy SMART information - try 'smartctl -x' for more

Adverteerder

Naam
depressie
Locatie
2132 EM, Hoofddorp, Nederland
Beoordeling
5 van 5 sterren
(64)
History
325 advertenties 11 actief
Actief sinds
zondag 24 februari 2019 19:56
Karma
9.162

Tips voor veilig handelen in Vraag & Aanbod

  • Pas op met onrealistische prijs Pas op met advertenties die een onrealistisch lage vraagprijs hebben.
  • Check echtheid van foto's Controleer of de advertentie is voorzien van authentieke foto's.
  • Informeer naar staat Informeer bij de verkoper naar de staat van het product en of er bijzonderheden zijn die de werking van het product beïnvloeden.
  • Verifieer verkoper Check de beoordelingen, registratiedatum en posthistorie van de verkoper.
  • Communiceer via DM Communiceer via directe berichten op Tweakers, zodat de fraudebestrijders van Tweakers deze communicatie in het geval van een conflict kunnen inzien.
  • Controleer politiedatabase Controleer de contactgegevens en het iban-nummer van de verkoper in de Politiedatabase.
Meer over handelen in Vraag & Aanbod
Delen:

Locatie van adverteerder

Locatie: 2132 EM, Hoofddorp, Nederland

Toon op kaart