Aangeboden door LinuZZ, woensdag 6 mei 2026 14:14, 31 views
Laatste wijziging op woensdag 6 mei 2026 15:12

Advertentiedetails


Vraagprijs € 7,50
Verzendkosten Exclusief
Staat Goede staat
Garantie Nee
Verzending ophalen en (pakket)post nationaal
Betaling contant, bitcoin en betaalverzoek

Beschrijving

Over na uitfaseren van diverse pctjes


smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.8.0-110-generic] (local build)

Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===

Model Family: Crucial/Micron RealSSD m4/C400

Device Model: M4-CT064M4SSD1

LU WWN Device Id: 5 00a075 1033070e0

Firmware Version: 010G

User Capacity: 64,023,257,088 bytes [64.0 GB]

Sector Size: 512 bytes logical/physical

Rotation Rate: Solid State Device

Form Factor: 2.5 inches

TRIM Command: Available, deterministic

Device is: In smartctl database 7.3/5528

ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6

SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)

Local Time is: Wed May 6 13:11:45 2026 UTC

==> WARNING: This drive may hang after 5184 hours of power-on time:

https://www.tomshardware.com/news/Crucial-m4-Firmware-BSOD,14544.html

See the following web page for firmware updates:

http://www.crucial.com/usa/en/support-ssd

SMART support is: Available - device has SMART capability.

SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===

SMART overall-health self-assessment test result: PASSED

General SMART Values:

Offline data collection status: (0x80) Offline data collection activity

was never started.

Auto Offline Data Collection: Enabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever

been run.

Total time to complete Offline

data collection: ( 295) seconds.

Offline data collection

capabilities: (0x7b) SMART execute Offline immediate.

Auto Offline data collection on/off support.

Suspend Offline collection upon new

command.

Offline surface scan supported.

Self-test supported.

Conveyance Self-test supported.

Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode.

Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine

recommended polling time: ( 2) minutes.

Extended self-test routine

recommended polling time: ( 4) minutes.

Conveyance self-test routine

recommended polling time: ( 3) minutes.

SCT capabilities: (0x003d) SCT Status supported.

SCT Error Recovery Control supported.

SCT Feature Control supported.

SCT Data Table supported.

SMART Attributes Data Structure revision number: 16

Vendor Specific SMART Attributes with Thresholds:

ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

1 Raw_Read_Error_Rate 0x002f 100 100 050 Pre-fail Always - 0

5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0

9 Power_On_Hours 0x0032 100 100 001 Old_age Always - 18087

12 Power_Cycle_Count 0x0032 100 100 001 Old_age Always - 36759

170 Grown_Failing_Block_Ct 0x0033 100 100 010 Pre-fail Always - 0

171 Program_Fail_Count 0x0032 100 100 001 Old_age Always - 0

172 Erase_Fail_Count 0x0032 100 100 001 Old_age Always - 32

173 Wear_Leveling_Count 0x0033 084 084 010 Pre-fail Always - 481

174 Unexpect_Power_Loss_Ct 0x0032 100 100 001 Old_age Always - 116

181 Non4k_Aligned_Access 0x0022 100 100 001 Old_age Always - 2898 567 2331

183 SATA_Iface_Downshift 0x0032 100 100 001 Old_age Always - 0

184 End-to-End_Error 0x0033 100 100 050 Pre-fail Always - 0

187 Reported_Uncorrect 0x0032 100 100 001 Old_age Always - 6500

188 Command_Timeout 0x0032 100 100 001 Old_age Always - 0

189 Factory_Bad_Block_Ct 0x000e 100 100 001 Old_age Always - 48

194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 0

195 Hardware_ECC_Recovered 0x003a 100 100 001 Old_age Always - 1631

196 Reallocated_Event_Count 0x0032 100 100 001 Old_age Always - 0

197 Current_Pending_Sector 0x0032 100 100 001 Old_age Always - 0

198 Offline_Uncorrectable 0x0030 100 100 001 Old_age Offline - 0

199 UDMA_CRC_Error_Count 0x0032 100 100 001 Old_age Always - 51

202 Perc_Rated_Life_Used 0x0018 084 084 001 Old_age Offline - 16

206 Write_Error_Rate 0x000e 100 100 001 Old_age Always - 0

SMART Error Log Version: 1

Warning: ATA error count 0 inconsistent with error log pointer 4

ATA Error Count: 0

CR = Command Register [HEX]

FR = Features Register [HEX]

SC = Sector Count Register [HEX]

SN = Sector Number Register [HEX]

CL = Cylinder Low Register [HEX]

CH = Cylinder High Register [HEX]

DH = Device/Head Register [HEX]

DC = Device Command Register [HEX]

ER = Error register [HEX]

ST = Status register [HEX]

Powered_Up_Time is measured from power on, and printed as

DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,

SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 0 occurred at disk power-on lifetime: 474 hours (19 days + 18 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:

ER ST SC SN CL CH DH

-- -- -- -- -- -- --

40 51 68 98 16 5c e0 Error: UNC 104 sectors at LBA = 0x005c1698 = 6035096

Commands leading to the command that caused the error were:

CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name

-- -- -- -- -- -- -- -- ---------------- --------------------

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 08 78 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

Error -1 occurred at disk power-on lifetime: 474 hours (19 days + 18 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:

ER ST SC SN CL CH DH

-- -- -- -- -- -- --

40 51 68 98 16 5c e0 Error: UNC 104 sectors at LBA = 0x005c1698 = 6035096

Commands leading to the command that caused the error were:

CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name

-- -- -- -- -- -- -- -- ---------------- --------------------

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 08 70 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

Error -2 occurred at disk power-on lifetime: 474 hours (19 days + 18 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:

ER ST SC SN CL CH DH

-- -- -- -- -- -- --

40 51 68 98 16 5c e0 Error: UNC 104 sectors at LBA = 0x005c1698 = 6035096

Commands leading to the command that caused the error were:

CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name

-- -- -- -- -- -- -- -- ---------------- --------------------

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 08 68 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

Error -3 occurred at disk power-on lifetime: 474 hours (19 days + 18 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:

ER ST SC SN CL CH DH

-- -- -- -- -- -- --

40 51 68 98 16 5c e0 Error: UNC 104 sectors at LBA = 0x005c1698 = 6035096

Commands leading to the command that caused the error were:

CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name

-- -- -- -- -- -- -- -- ---------------- --------------------

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 08 60 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

Error -4 occurred at disk power-on lifetime: 474 hours (19 days + 18 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:

ER ST SC SN CL CH DH

-- -- -- -- -- -- --

40 51 68 98 16 5c e0 Error: UNC 104 sectors at LBA = 0x005c1698 = 6035096

Commands leading to the command that caused the error were:

CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name

-- -- -- -- -- -- -- -- ---------------- --------------------

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 60 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 80 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

25 00 80 00 16 5c e0 00 19d+18:13:00.000 READ DMA EXT

SMART Self-test log structure revision number 1

No self-tests have been logged. [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1

SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS

1 0 0 Not_testing

2 0 0 Not_testing

3 0 0 Not_testing

4 0 0 Not_testing

5 0 0 Not_testing

Selective self-test flags (0x0):

After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.

The above only provides legacy SMART information - try 'smartctl -x' for more

Adverteerder

Naam
LinuZZ
Locatie
3214 TV, Zuidland, Nederland
Beoordeling
5 van 5 sterren
(115)
History
324 advertenties 13 actief
Actief sinds
zaterdag 31 januari 2004 14:05
Karma
23.310

Tips voor veilig handelen in Vraag & Aanbod

  • Pas op met onrealistische prijs Pas op met advertenties die een onrealistisch lage vraagprijs hebben.
  • Check echtheid van foto's Controleer of de advertentie is voorzien van authentieke foto's.
  • Informeer naar staat Informeer bij de verkoper naar de staat van het product en of er bijzonderheden zijn die de werking van het product beïnvloeden.
  • Verifieer verkoper Check de beoordelingen, registratiedatum en posthistorie van de verkoper.
  • Communiceer via DM Communiceer via directe berichten op Tweakers, zodat de fraudebestrijders van Tweakers deze communicatie in het geval van een conflict kunnen inzien.
  • Controleer politiedatabase Controleer de contactgegevens en het iban-nummer van de verkoper in de Politiedatabase.
Meer over handelen in Vraag & Aanbod
Delen:

Locatie van adverteerder

Locatie: 3214 TV, Zuidland, Nederland

Toon op kaart

Reacties

Reageren onder advertenties is niet meer mogelijk. Reageren is alleen mogelijk door de adverteerder een bericht te sturen.